Recent activity by Adam Vorisek-
What are the Lincoln Street fan blades made out of?
Lincoln Street blades are constructed of glass-reinforced nylon. This gives them a high rigidity preventing the fan blades from drooping over time.
-
Hbb Fault Code 60, AirVolution/AirLegacy Troubleshooting (Public)
An Hbb fault (fault code 60 on the touchscreen) is a hardware baseblock fault. This fault code indicates that the factory jumper between the H1 and HC terminals has been removed or modified. This j...
-
How Long Does It Take To Get A Fan?
Lead times vary by product line and can be found on the individual product pages on our website here. For any lead times that are not listed on our website, please contact a MacroAir Sales Represen...
-
Is There A Hardwired Remote Control Option For The Lincoln Street Fan?
The Lincoln Street Fan is sold only with the standard wireless remote. It may be possible to use a third party wired remote via ©Bond Bridge, but MacroAir does not have any recommendations or guida...
-
CE Fault Code 20 - AirVolution/AirLegacy Troubleshooting (Public)
A CE fault code (fault code 20 on the touchscreen) indicates a modbus comms fault. This means that communication has been lost between the VFD and the control source (touchscreen controller or AirL...
-
How Do I Schedule A Service Call For Someone To Take A Look At My Fans?
To schedule a service call for someone to visit your site for diagnosis and/or repairs, please submit a support ticket here.
-
Can The Lincoln Street Fan Be Mounted On A Sloped Ceiling?
The Lincoln Street fan can be mounted to a sloped ceiling, but the maximum angle (or slope) of the ceiling cannot be greater than 20 degrees (or 4:12 pitch).
-
CALL Alarm, AirVolution/AirLegacy Troubleshooting (Public)
A CALL alarm indicates a communication transmission error. This means that communication has not been established between the VFD and the control source (touchscreen controller or AirLynk). Note th...
-
What Is My Order Status? Can You Provide Tracking Information?
For Sales orders, please reach out to your MacroAir Sales Representative at (866)668-3247 option 1 with your order information and they will be able to update you. For warranty orders, please reply...
-
OH (Fault Code 9), OH1 (Fault Code 10), OH3 (Fault Code 29), AirVolution/AirLegacy Troubleshooting (Public)
An OH, OH1, or OH3 fault (fault codes 9, 10, and 29 on the touchscreen, respectively) is an overheating fault. The VFD has exceeded the rated temperature. Below are some possible causes and solutio...