SC Fault Code 5 - AirVolution/AirLegacy Troubleshooting (Public)
A SC fault (fault code 5 on the touchscreen) is a short circuit fault. The VFD has detected a short circuit on the output. Below are some possible causes. 1. The motor cable is not properly wired...
-
What Are The Unlabeled Yellow Wires In The Motor For?
Some AirVolution and AirLegacy fans have two yellow wires with connectors on the end. These wires are not used by MacroAir and can be ignored. You only need to utilize the wires that are on the pos...
-
What Time Do You Open?
MacroAir's business hours are Monday through Friday 7AM-4PM Pacific Standard Time, excluding holidays. Technical Support is available 6AM-4PM PST. We are available for all of your inquiries during ...
-
What Torque Specification Do I Use For Blade Bolts And Other Hardware?
Blade bolts for XL blades used on every HVLS model except the AVD370 should be torqued to 23 ft-lbs. There is no specific torque spec for the XS blades used on the 370. Torque specs for other hardw...
-
Can I Run My Fans From A Building Management System (BMS) With An AirLynk In Conjunction With Standard Touchscreens/Controller 4s/Controller 30s?
Standard touchscreens, Controller 4s, and Controller 30s are standalone products and cannot interface with a AirLynk/BMS. If you want to interface our fans with a BMS and have a single local contro...
-
What Are The CFM Numbers of the Lincoln Street Fan?
The Lincoln Street fan has 10,155-15,150 CFM of airflow depending on the diameter.
-
rr Fault Code 15 - AirVolution/AirLegacy Troubleshooting (Public)
An rr fault (fault code 15 on the touchscreen) is a dynamic braking resistor fault. This is an error with internal VFD components. It is possible that a power cycle can fix this (leave the incoming...
-
What Is The Price Of A MacroAir Fan?
Prices for many of our fans can be found on the product pages here. For fan cost and other pricing questions that are not found on our website, please contact our Sales team at (866)668-3247 option...
-
My Fan Looks Like It Is Running Slow. What's Going On?
If you are running your fan in the reverse direction, MacroAir limits the speed of the reverse function to 50% compared to the forward direction and older remotes. This was done for efficiency and ...
-
Can I Order A Controller 4, Controller 30, AirLynk, Dual Control, Or Local Override For Existing Fans On Standard Remotes?