Adam Vorisek
- Total activity 603
- Last activity
- Member since
- Following 0 users
- Followed by 0 users
- Votes 0
- Subscriptions 411
Articles
Recent activity by Adam Vorisek-
I Am Trying To Change Out The Motor On An AirVolution, But The New Motor Is Taller And Does Not Fit. Did You Send Me The Wrong Part?
The Department of Energy updated motor requirements around 2017 which forced all motor manufacturers to increase the size of the motors we use on our fans. While the motor is taller than your origi...
-
What Is ©Bond Bridge?
©Bond Bridge is a third-party device that allows the Lincoln Street fan and other home devices to connect to your home WiFi network. This allows the control of our fan from smartphones, tablets, an...
-
PF Fault Code 27 - AirVolution/AirLegacy Troubleshooting (Public)
A PF fault (fault 27 on the touchscreen) is an input phase loss fault. The VFD detected that an input phase is missing. Below are the possible causes and solutions. 1. The supply voltage is too ...
-
Why Do I Need To Contact You For A Price Quote Instead Of Being Able To View Prices On Your Website?
We understand that in today’s digital world, many people expect pricing to be readily available online. However, our products are highly customizable to meet the specific needs of each customer. Th...
-
I Think There Might Be An Issue With My VFD. Do You Have A VFD Program Or Parameter List?
VFD troubleshooting and parameter changes are best done with our Technical Support personnel over the phone. Any unauthorized changes to VFD programming will void the warranty of the fan. If you re...
-
What Is The Password On The Controller 30?
The default username and password for the Controller 30 are both "admin", all lower-case.
-
Can I Buy ©Bond Bridge Through MacroAir?
©Bond Bridge must currently be purchased separately, but we hope to be able to offer it on our website soon.
-
OV Fault Code 8 - AirVolution/AirLegacy Troubleshooting (Public)
A OV fault (fault code 8 on the touchscreen) is a mains overvoltage fault. The VFD has detected that the input power has exceeded the drive's rating. Important Note: If you are seeing an "OU" fa...
-
How Do I Get A Quote For New Fans Or Parts?
For fan and parts quotes, please contact our Sales team at (866)668-3247 option 1. Our business hours are Monday-Friday 7AM-4PM PST, excluding holidays. You can also leave a message with our Sales ...
-
Your Motor Cable Leads Are Not Labeled. Will The Equipment Be Damaged If They Are Hooked Up In The Wrong Order?
The worst that will happen if leads 1, 2, and 3 from the VFD are not landed in the correct order on leads 1, 2, and 3 on the motor is that the motor will spin in the reverse rotation. Swapping two ...